● Advanced dual-core DSP control technology and 3-level technology

● Active Power Factor Correction Technology, input power factor up to 0.99

● System efficiency improved to 95%, energy saving rate is doubled

● Output power factor 1.0

● Working efficiency up to 98% in ECO mode

● Fan speed varies intelligently with load, reducing noise and extending its service life

● Standard 5A Charger, Optional 12A Charger (long time model)

● With ultra wide input voltage range (80 ~ 288Vac) and frequency range (40-70Hz)

● 50 Hz / 60 Hz auto-sensing frequency

● 50 Hz / 60 Hz frequency conversion mode

● Flexible battery configuration (settable 10-22 pcs batteries)

● Linear derating in low voltage input reducing battery discharging time, extending the service life of battery

● Intelligent battery management, automatic equalized and float charging control, charger dormancy control, improving the reliability of charger and extending the battery life

● Powerful background software for parameters configuration and online upgrade

● Effective hardware and software protection, robust self-diagnosis function, abundant event log for future check

● Standard RS232, EPO, Smart card slot

● Optional SNMP card, Wi-Fi card, 4G card and SMS alarms, Dry contacts, Parallel kit, RS485

MODEL ES906 ES9010
Capacity 6kVA / 6kW 10kVA / 10kW
INPUT
Input wiring Single-phase three-wire (1Φ + N + PE)
Rated voltage 208 / 220 / 230 / 240Vac
Voltage range 176~288Vac (full load); 90~176Vac (linear derating to 30%)
Rated frequency 50/60Hz
Frequency range 40~70Hz
Power factor ≥ 0.99
Bypass voltage range - 40% ~ +15% (settable)
Input current THDi ≤ 5%
OUTPUT
Output wiring Single-phase three-wire (1Φ + N + PE)
Rated voltage 208 (PF=0.9) / 220 / 230 / 240 Vac
Voltage regulation ± 1%
Frequency Synchronized with utility in mains mode; 50/60Hz±0.1% in battery mode
Waveform Sinusoidal
Power factor 1
Output voltage THDv <1% (full linear load); <4% (full non-linear load)
Crest factor 3:1
Overload 105% ~ 110% for 10min, 110% ~ 125% for 1min, 126% ~ 150% for 30s
BATTERIES
DC voltage Default 192Vdc (120~264Vdc)
Number of battery Default 16pcs, settable 10-22pcs (10~15pcs linear derating to 50%)
Inbuilt battery (standard model) 12V / 7Ah×16 12V / 9Ah×16
Charger power Standard: 1A(def), 1~5A set; Long time: 5A(def), 1~5A set; 12A(opt)
Charger voltage precision 1%
Recharge time Standard: 90% in 8 hrs; Long time: depend on battery capacity
SYSTEM
Efficiency ≥ 94% at 100% load, max. 95% at 60% load, ≥ 98% in ECO mode
Transfer time 0 ms
Protections Short-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failure
Max. number of parallel connections 4
Communications Std: RS232, EPO, Smart card; Opt: SNMP, Wi-Fi, 4G, SMS, dry contacts, parallel kit, RS485
Display LCD + LED
OTHERS
Operating temperature 0℃ ~ 40℃
Storage temperature -25℃ ~ 55℃ (without battery)
Relative humidity 0 ~ 95% (non-condensing)
Altitude <1000m, derating 1% per 100m from 1000~2000m
IP rating IP 20
Noise level at 1m <58 dB
Dimensions (W×D×H) (mm) 191×500×515 (S), 191×440×350 (H)
Packaged dimensions (W×D×H) (mm) 310×654×600 (S), 318×570×475 (H)
Net weight (kg) 49.5(S), 14.5(H) 58.5(S), 15.5(H)
Gross weight (kg) 58(S), 16(H) 67(S), 17(H)

• S means standard model; H means long time model.
• All specifications are subject to change without notice.